Good day all,
I'm new on this forum. I have a question regarding the CNC (Control Network C).
I recently did the PN-4 (CNC) and everything was working fine.
Today, I’ve found alarms and errors as below through the web interface:
Any idea how to fix these problems?
1. Status Summary
The Status Summary Web page displays information about the status and the overall health of the server.
SERVER STATUS
Cluster ID: 001
Duplication: sw
Standby Busied? no
Standby Refreshed? yes
Standby Shadowing: on
Duplication Link: up
Active RAID HDD Status: 2
Elapsed Time since Init/Interchange: 490d 01:39:55
District2 Disrtict1
ID: 002 (2) ID: 001 (1)
Mode: Active Mode: Standby
Major Alarms: yes Major Alarms: no
Minor Alarms: yes Minor Alarms: no
Control Network: 4 / 4 / 4 Control Network: 3 / 3 / 4
Processor Ethernet: unused Processor Ethernet: unused
PE Priority: PE Priority:
Server Hardware: okay Server Hardware: okay
Processes: okay Processes: okay
RAID HDD Status: 2
Major alarm and Major alarm on Active server: Control Network: 4 / 4 / 4
2. IPSI Version Results are visible from Active server IP-address:
View IPSI Version Results
This may take 1 seconds ...
IPaddress IPSI Name IPSIBoard HW# FW#
10.191.240.200 ipsi-A04a TN2312BP 15 30
198.152.255.3 ipsi-A03b TN2312BP 15 30
198.152.254.3 ipsi-A03a TN2312BP 15 30
198.152.255.2 ipsi-A02b TN2312BP 15 30
198.152.254.2 ipsi-A02a TN2312BP 15 30
198.152.255.1 ipsi-A01b TN2312BP 12 12
198.152.254.1 ipsi-A01a TN2312BP 15 30
3. IPSI Version Results is not visible from Standby server IP-address:
View IPSI Version Results
This may take 1 seconds ...
IPaddress IPSI Name IPSIBoard HW# FW#
10.191.240.200 ipsi-A04a Not available.
198.152.255.3 ipsi-A03b TN2312BP 15 30
198.152.254.3 ipsi-A03a TN2312BP 15 30
198.152.255.2 ipsi-A02b TN2312BP 15 30
198.152.254.2 ipsi-A02a TN2312BP 15 30
198.152.255.1 ipsi-A01b TN2312BP 12 12
198.152.254.1 ipsi-A01a TN2312BP 15 30
4. IP SERVER INTERFACE INFORMATION AS BELLOW:
IP SERVER INTERFACE INFORMATION
Port Pri/ Primary/ Primary/ Primary/ State Of
Ntwk Sec Secondary Secondary Secondary Serv Control Health
Num Bd Loc IP Address Host Name DHCP ID State State C P E G
---- ------ --------------- ---------------- --------- ----- ------- -------
1. 1A01 199.172.254.1 199.172.254.1 ipsi-A01a IN actv-aa 0.0.0.0
1B01 199.172.255.1 199.172.255.1 ipsi-A01b IN standby 0.0.0.0
2. 2A01 199.172.254.2 199.172.254.2 ipsi-A02a IN actv-aa 0.0.0.0
2B01 199.172.255.2 199.172.255.2 ipsi-A02b IN standby 0.0.0.0
3. 3A01 199.172.254.3 199.172.254.3 ipsi-A03a IN actv-aa 0.0.0.0
3B01 199.172.255.3 199.172.255.3 ipsi-A03b IN standby 0.0.0.0
4. 4A01 10.189.2.67 10.189.2.67 ipsi-A04a IN actv-aa 0.0.0.0
Note: there is only one IPSI card in the PN-4 with 10.189.2.67
Software Version:
1. CM Reports as: R015x.02.1.016.4
2. CM Release String: S8800-015-02.1.016.4
NO any alarms/errors from the ASA (Avaya site administration)
Thanks, Yerbol