You should have see "SP-REG-M" minor alarm. You can look at display alarms and search "resolved" and enter the time frame for when the lsp was down.
On Thursday, December 7, 2017 01:33:38 PM PST, luc parent <
iaug-ags@lists.iaug.org> wrote:
Hi,
we have a location with an ESS HP DL360 server configured as backup CM with a G650 cabinet.
IPSI cards on that cabinet is registerred on our Primary CM to another location.
Someone shut down the HP DL360 by error and we never got an alarm saying that it was down.
Couple days after, we did a "list survivable-processor" and we see that the ESS wasn't registered.
My question, it is possible to configure the Primary CM to send alarm when backup CM goes offline??
when I verified the "disp alarms" , I didn't see alarm for it.
Thanks!
Luc P.